Learn More About Dielectric Withstand Or Hipot Tester Procedures From An Industrial Engineering Perspective

By Carl Hughes


Dielectric Strength or hipot test procedure is conducted by generating high voltage power between wire tested to the ground, most likely locomotive chassis. When overloaded current leaks or when an arc transpires, test fall short. Insulation Resistance measuring usually presents numerical values on resistance insulation indication. Facts on hipot testers measuring work are discussed.

Hi Pot can either be AC DC, done occasionally or at assembly line end among others. Stress test result commonly indicates Pass Fail in view of current leak. For a few structures, this may demonstrate risk. Testing median voltage cable might likewise demonstrate risk.

Dielectric strength presents maximum electrical field that pure material may withstand underneath ideal setting without tearing down or without experiencing failure with its insulating properties. Theoretical dielectric strength is material intrinsic property on bulk material and independent configuration material or electrodes with which field is put to use. This inherent dielectric withstand corresponds what is being measured using untouched materials under controlled laboratory settings.

At breakdown, electrical fields free bounded electrons. If applied electrical fields are sufficiently high, freed electrons from surrounding radiation might accelerate with velocities which could liberate further electrons during neutral atom molecule collision in a course termed avalanche breakdown. Avalanche Breakdowns take place somewhat quickly, in nanoseconds normally, resulting into an electrically conducive path structure and disrupting electron release throughout an object. For concrete materials, avalanche breakdown event rigorously debase, even demolish said materials insulating potential.

With respect to insulations and dielectric testings differences, none exists. Contrast between insulation and di electric testing does not matter. Dielectric quality basically demonstrates how well an insulator is. About testing, frequency test ought to be controlled by what voltage insulating substance should expect amid its functional period. Which implies you ought keep from DC quality testing aspects that will be utilized for AC 50 or 60 Hertz applications.

While they are just two separate and very different procedures, these terms are wildly thrown around interchangeably in electrical industry. So you cannot easily rely on those names accurately describe what is being tested alongside how test was performed. For example, in Practical Guide Di electric Tests, where Di electric Tests in their definition is an Insulation Resistance tests HiPot tests combination.

Whereas, generally, HiPot tester currently used unto Dielectric Strength value test will suit utilization towards Insulation Resistance experiments. Precise term usage will heavily depend on firm you work for, deal with. As a precautionary measure, you must always read set method information yourself.

Insulation Resistance analyzation would dependably indicate DC. Di electric Quality test will typically be AC, however, could be DC. In the event that one checks whether one or the other could be skipped as they examine same things, investigations were done previously. Both are required as they give distinctive information as their final data.

An emphasis on these tests interchangeability would trivial because, at the end of the day, most insulated materials go through both as it unwise generally to pigeon hole your substance product into using only one frequency, electrical transmission when most cases it will work for both assuming they have same amount. Using 48v DC system, generally using materials with secondary rating around 600v ac should suffice. Ultimately as long as one does not fail hipot, everyones happy regardless of insulated matter used.